T8 LED Driver - DEK-T8HR-22W-480MA
Place of Origin: Guangdong China (Mainland) | Brand Name: DADEKAN | Model Number: DEK-T8HR-22W-480MA |
MODEL | DEK-T8HR-22W-480MA | ||||
Input | Input Voltage | 90VAC~277VAC | |||
VoltageRange | 100VAC~277VAC | ||||
Start-up Voltage(-25~70°C) | 90VAC | ||||
FrequencyRange | 47Hz~63Hz | ||||
Power Factor(@25°C) | >0.95@220VAC, Full Load | ||||
AC Current(@25°C) | 0.25AMax. | ||||
Inrush Current(@ 25°C) | 10AMax. | ||||
Output | OutputVoltage Range | 30V~40V | |||
OutputCurrent | 480mA | ||||
OutputPower | 10~22W | ||||
ConversionEfficiency (@25°C) | 86% @220VAC, Full Load | ||||
No-load Output Voltage | 50V Max. | ||||
Line Regulation(@-25~70°C) | ±5% | ||||
Accuracy Constant(@-25~70°C) | ±5% | ||||
Set-up Time(@25°C) | <1S@220VAC,<2S@110VAC | ||||
Temperature Coefficient(@-25~70°C) | ±0.03%/°C | ||||
Overshoot(@-25~70°C) | ±5% No-load Rated Voltage | ||||
Output Ripple & Noise | 0<Ta≤70°C | 130mVP-P | |||
-25≤Ta≤0°C | 200mVP-P | ||||
Protection(-25~70°C) | Input Electrical | Low Voltage Protection | / | ||
Over VoltageProtection | / | ||||
Output Electrical | Shorted Circuit Protection | Hiccup, Auto Recovery | |||
No-load Protection | Constant Voltage | ||||
OverTemperatureProtection | / | ||||
Environmental Requirement | Vibration | 10~500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z, axes | |||
Impact | 20G/11mS pulse,3times at each X, Y, Z axes | ||||
Storage Temp. & Hum. | -40°C~85°C; 10%~95%RH No condensing | ||||
Operating amb. Temp. & Hum. | -40°C~60°C; 20%~90%RH No condensing | ||||
Altitude | 3000m | ||||
IPX | / | ||||
Safety &. EMC | Isolation Resistance | Input--out: 100M OHMS | |||
Withstand Voltage | Input--out: 3KVAC/10mA | ||||
Ground Impedance | / | ||||
Safety Standards | IEC 61347-2-13/GB19510.14/UL8750 | ||||
EMI | CE | EN55015 Class B/FCC Part15 B | |||
RE | EN55015 Class B/FCC Part15 B | ||||
Harmonic Current | EN6100-3-2, Class C | ||||
EMS | CS | EN61000-4-6 Level 3 Class B | |||
RS | EN61000-4-3Level3Class B | ||||
ESD | EN61000-4-2 Level 4 | ||||
Surge | EN61000-4-2Level 4 | ||||
Power Frequency Harassment | EN61000-4-8Level3 | ||||
EFT | EN61000-4-4Level3 | ||||
Interrupt, Drop | / | ||||
Other | Dimensions (L * W * H) | 290mmX 17mm X 10mm | |||
Package | / | ||||
Cooling Method | VentilationCooling | ||||
Reliability | Burn-in | The power supply shall go a minimum of 4 Hours burn-in test under full load condition. | |||
Design MTBF | 50,000Hrs @25°C, MIL-HDBK-217 Method 2 Components Stress Method | ||||
Design Electrolytic Capacitor Life | 17520Hrs @50°CFull load and units continuously working | ||||
Note | Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. Test spare parts: test voltage for 500 VDC, 65% RH @25°C. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. | ||||
Minimum Negative Load Requirements | None | ||||
Accessories | / |
Packaging Detail:In box with plastic tube, or according to the buyer's requirements. |
Delivery Detail:7 Days |