1. Output:
1) DC Voltage: DC12V
2) Rated currrent: 12.5A
3) Current range: 0~12.5A
4) Raged power: 150W
5) RIPPLE & NOISE (max.) Note.2: 120mVp-p
6) VOLTAGE ADJ. RANGE: 11.4 ~ 13.5V
7) VOLTAGE TOLERANCE Note.3: ±1%
8) VOLTAGE TOLERANCE Note.3: ±0.5%
9) LOAD REGULATION Note.5: ±0.5%
10) SETUP, RISE TIME:800ms, 20ms/230VAC
11) HOLD UP TIME (Typ.):24ms/230VAC
2. Input:
1) VOLTAGE RANGE:90 ~ 132VAC / 180 ~ 264VAC selected by switch
2) FREQUENCY RANGE:47 ~ 63Hz
3) EFFICIENCY (Typ.):83%
4) AC CURRENT (Typ.): 2A/230VAC
5) INRUSH CURRENT (Typ.): COLD START 45A
6) LEAKAGE CURRENT: <2mA / 240VAC
3. Protection:
1) OVERLOAD 110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
2) OVER VOLTAGE:
13.8 ~ 16.2V
Protection type : Shut down o/p voltage, re-power on to recover
4. SAFETY & EMC (Note 6)
1) SAFETY STANDARDS: UL60950-1, CB(IEC60950-1),CCC GB4943 approved
2) WITHSTAND VOLTAGE:I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
3) ISOLATION RESISTANCE: I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 °C/ 70% RH
4) EMC EMISSION: Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
5) EMC IMMUNITY:Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-1, light industry level, criteria A
5. Others
1) MTBF: 433.3K hrs min. MIL-HDBK-217F (25°C)
2) DIMENSION: 199*98*38mm (L*W*H)
3) PACKING:0.7Kg; 20pcs/15Kg/0.72CUFT
6. Notes:
1) All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2) Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3) Tolerance : includes set up tolerance, line regulation and load regulation.
4) Line regulation is measured from low line to high line at rated load.
5) Load regulation is measured from 0% to 100% rated load.
6) The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”