50W CE UL LED emergency battery pack - 184501
50W CE UL LED emergency battery pack, 1. For normal operation and emergency operation of LEDs, no need extra LED driver, 2. CE - details see: https://www.lightinghere.com/50w-ce-ul-led-emergency-battery-pack-10006160
Place of Origin: China (Mainland) | Brand Name: Phenix Lighting | Model Number: 184501 | Battery Type: selectable |
Material: aluminium house | Usage: emergency | Voltage: 120-277V | Rated Power: 50 Watt max. |
Approval: CE and UL |
50W CE UL LED emergency battery pack
- For normal operation and emergency operation of LEDs, no need extra LED driver
- CE & UL approval
- Constant current, multi-current selectable output
- Normal mode LED soft start, emergency mode conversion within 0.3 seconds
- 1-10V dimmable
- Emergency mode can choose 25%, 50%, 75%, 100% output of normal mode
- Auto Test
- aluminium housing
- Class I
Specification | 184500 | 184501 |
Rated voltage | 120-277VAC 50/60Hz | 120-277VAC 50/60Hz |
Rated current | 0.3A(Max) | 0.5A(Max) |
Rated power | 30W (Max) | 50W (Max) |
Output voltage | 3~42VDC | 3~42VDC |
Operation frequency | 320kHz≥f≥50kHz | 320kHz≥f≥50kHz |
Power Factor | ≥0.9 | ≥0.9 |
Battery | 1.0-4Ah, 9.6V Ni-Cd/Ni-MH/LiFePO4 | 1.0-4Ah, 9.6V Ni-Cd/Ni-MH/LiFePO4 |
Charging time | 24 Hours | 24 Hours |
Discharge time | >90 Minutes | >90 Minutes |
Charging current | 0.40A(Max) | 0.40A(Max) |
Life time | 5 years | 5 years |
Charging cycles | >500 | >500 |
Operation temperature | Ta: -20~50°CTc: 70°C | Ta: -20~50°CTc: 70°C |
Output current | 150mA, 250mA, 300mA, 350mA, 400mA, 450mA, 500mA, 600mA±3% | 600mA, 700mA, 750mA, 800mA, 850mA, 900mA,950mA, 1000mA±3% |
Efficiency | 80% | 80% |
Abnormal protection | Over load,Inrush current limiting,over temperature, open circuit, short-circuit Protection with auto-reset | Over load,Inrush current limiting,over temperature, open circuit, short-circuit Protection with auto-reset |
Wire | 1. 5~2.5mm2 | 1. 5~2.5mm2 |
EMC& EMF standard | EN 55015, EN 61547, EN61000-3-2, EN61000-3-3; EN62493 | EN 55015, EN 61547, EN61000-3-2, EN61000-3-3; EN62493 |
Safety standard | EN 61347-1, EN 61347-2-13 ,EN61347-2-7, UL924, UL8750 | EN 61347-1, EN 61347-2-13 ,EN61347-2-7, UL924, UL8750 |
Batteryfor 184501 | ||||
Current(mA) | Emergency power rate | |||
25% | 50% | 75% | 100% | |
9.6V battery(Ah) | 9.6V battery(Ah) | 9.6V battery(Ah) | 9.6V battery(Ah) | |
600 | 1.00 (Ni-Cd AA) | 2.00 (Ni-Cd SC) | 3.00 (LiFePO4) | 4.00 (Ni-Cd D) |
700 | 1.50 (Ni-Cd SC) | 3.00 (LiFePO4) | 4.00 (Ni-Cd D) | 4.00 (Ni-Cd D) |
750 | 1.50 (Ni-Cd SC) | 3.00 (LiFePO4) | 4.00 (Ni-Cd D) | 4.00 (Ni-Cd D) |
800 | 1.50 (Ni-Cd SC) | 3.00 (LiFePO4) | 4.00 (Ni-Cd D) | 4.00 (Ni-Cd D) |
850 | 1.50 (Ni-Cd SC) | 3.00 (LiFePO4) | 4.00 (Ni-Cd D) | 4.00 (Ni-Cd D) |
900 | 1.50 (Ni-Cd SC) | 3.00 (LiFePO4) | 4.00 (Ni-Cd D) | 4.00 (Ni-Cd D) |
950 | 2.00 (Ni-Cd SC) | 4.00 (Ni-Cd D) | 4.00 (Ni-Cd D) | 4.00 (Ni-Cd D) |
1000 | 2.00 (Ni-Cd SC) | 4.00 (Ni-Cd D) | 4.00 (Ni-Cd D) | 4.00 (Ni-Cd D) |
Packaging Detail:industry packing |
Delivery Detail:45 days |